IP68 Soil Moisture Sensor Humidity Transducer for Garden Greenhouse Agriculture 0‑100% 2s ResponseOutput 0‑2V 7‑24V
IP68 Soil Moisture Sensor Humidity Transducer for Garden Greenhouse Agriculture 0‑100% 2s ResponseOutput 0‑2V 7‑24V — image 2
IP68 Soil Moisture Sensor Humidity Transducer for Garden Greenhouse Agriculture 0‑100% 2s ResponseOutput 0‑2V 7‑24V — image 3
IP68 Soil Moisture Sensor Humidity Transducer for Garden Greenhouse Agriculture 0‑100% 2s ResponseOutput 0‑2V 7‑24V — image 4
IP68 Soil Moisture Sensor Humidity Transducer for Garden Greenhouse Agriculture 0‑100% 2s ResponseOutput 0‑2V 7‑24V — image 5
IP68 Soil Moisture Sensor Humidity Transducer for Garden Greenhouse Agriculture 0‑100% 2s ResponseOutput 0‑2V 7‑24V — image 6
Swipe to see all 6 photos

Garden & Outdoor

IP68 Soil Moisture Sensor Humidity Transducer for Garden Greenhouse Agriculture 0‑100% 2s ResponseOutput 0‑2V 7‑24V

Item price

$95.95

or 4 payments of $23.99 with Afterpay & Zip

Delivery is calculated at checkout — the total you see before you pay is the total you pay.

In stock · ready to order

Estimated delivery Wed, 23 Sept – Fri, 9 OctShips from our overseas supplier · we email your tracking number as soon as it ships. An estimate, not a guaranteed delivery date.

Delivery & checkout

Quantity
1
Total to pay$95.95+ delivery
VISAAMEXafterpayZip.

$95.95

Delivery at checkout

Product details

Working and Storage Conditions: Operating Voltage 7-24V 12-24V 7-24V Working Current 3-5mA 3-25mA 3-5mA Output Signal Output Signal 0-2V DC 4-20mA RTU Protocol RTU Protocol Commands of RTU Protocol Include: Read the value of soil moisture (the factory is station 2) Working Principle: FDR frequency domain method uses the principle of electromagnetic pulse to measure the dielectric constant (ε) of the soil according to the propagation frequency of electromagnetic waves in the medium to obtain the soil volumetric water content (θv). Scope of Application: Suitable for water-saving agricultural irrigation, greenhouses, flowers and vegetables, grassland pastures, soil rapid testing, plant cultivation, scientific experiments, underground oil, gas pipelines and other pipeline anti-corrosion monitoring fields. Wiring: Line Color Red Line Black Line White Line Simulation Power Positive Power Negative Signal Line Color Red Line Black Line Yellow Line Brown Line RS485 Power Positive Power Negative 485A 485B Example of Read Command Format: 02 03 00 00 00 01 84 39 Note: The first byte 02 at the beginning is the station number. If you have modified the station number setting, you should change the first digit 02 to the station number you set. The last two digits 84 39 are CRC16 checksums, and customers need to calculate them by themselves. Example of Command Format of Returned Data: 02 03 02 01 1F BC 1C Note: The 4 and 5 bits of 01 1F are the moisture value, and BC 1C is the returned CRC check. Analysis Method of Soil Moisture Data: Moisture=0X011F/10=28.7% Modify Own Station Number: Method 1: Know the current station number and send the following command 02 10 10 00 00 01 02 00 03 E3 60 Its function is to change the station number from No. 2 to No. 3. Note: Replace italicized characters with the original station number, and replace the regular characters with the value of the target station number that you want to modify. Sending requires the customer to calculate the CRC value by himself. Method 2: Know the current station number and send the following command 02 06 10 00 00 03 CD 38 Its function is to change the station number from No. 2 to No. 3. Note: Replace the italicized characters with the original station number, and replace the regular characters with the value of the target station number that you want to modify. Sending requires the customer to calculate the CRC value by himself. Method 3: Forget the original station number, you need to connect the product to the computer alone, pay attention There can be no other 485 products on the bus. Use station 0 to operate them. The instructions are as follows: 00 10 10 00 00 01 02 00 03 FA 00 Note: The big characters are the target station number value that you want to modify. The customer calculates the CRC check value by himself. This sensor uses the FDR method (frequency domain method) to measure soil moisture, which can correspond to the soil volumetric moisture content. The FDR method (frequency domain method) measuring soil moisture is mainly related to the pH of the measured soil, the density of the soil, the soil quality, and the depth of the measurement. Fault Analysis and Elimination: Check whether the power supply range is normal Check whether the line is virtual Check whether the power supply voltage meets the requirements Care and Maintenance: This instrument is a scientific and technological product with excellent design and functional principles, and attention should be paid to maintenance. The following suggestions will help you effectively use maintenance services.

  • Product Composition: Soil moisture sensor is composed of a power supply module, a transmission module, a zero drift and temperature compensation module, and a data processing module.
  • Powerful Function: The sensor has built in signal sampling and amplification, zero drift and temperature compensation functions, which have little impact on soil quality and are widely used in a wide range of areas.
  • 0‑100% Measurement Range: High measurement accuracy, reliable performance, quick response, good interchangeability, and high data transmission efficiency.
  • Compact Design: This soil moisture sensor has a small and light appearance, which is easy to carry and connect. The cable length is about 1.5 meters, which can meet the needs of use.
  • Long Lasting Use: Supports dielectric constant signal output, good sealing, IP68 protection level, can be directly buried in soil and used, not easy to be corroded or rusted.
  • The sensor output signal is abnormal — Check whether the supply voltage is stable
  • The sensor has no signal output — Check whether the positive and negative poles of the power supply and the ground wire are connected correctly
  • Prevent the instrument from being scratched, maintain the integrity of the external protective film, and increase the service life of the instrument.
  • When using the instrument, please fix the connection parts firmly to avoid damage to the instr
Specifications
Item Type
Soil Moisture Sensor
Material
ABS
Weight
Approx. 141g / 5oz
Probe Material
Stainless Steel
Sealing Material
Epoxy Resin
Measurement Parameter
Soil Volumetric Water Content
Measuring Range
0-100%
Measurement Accuracy
±3%
Resolution
0.1%
Measurement Area
A cylinder with a diameter of 7cm and a height of 7cm surrounding the central probe with the central probe as the center
Probe Diameter
Approx. 3mm / 0.12in
Response Time
2s
Cable Length
Approx. 1.5m / 4.9ft
Working Temperature
-40-85℃
Working Humidity
0-100%RH
Storage Temperature
-40-125℃
Storage Humidity
80% (No Condensation)
Protection Level
IP68
V
Voltage Type
A
Current Type
R
RS485 Type
Communication Method
RS485 communication, transmission distance 1000 meters
Communication Rate
9600, n, 8, 1
Communication Protocol
RTU protocol, the factory station number (device address) is station 2, which can be modified as needed.
Warranty & returns

Change of mind? Return it within 30 days in original, unused condition.

Anything faulty, damaged in transit, or not as described is always covered under the Australian Consumer Law — you're entitled to a repair, replacement or refund. Manufacturer warranty also applies where the maker offers one.

Delivery policy

We deliver right across Australia. Your delivery cost is worked out from your address at checkout — the total you see before you pay is the total you pay, with no surprises after.

Orders are dispatched by our supplier or delivery partner and tracked to your door. You'll get tracking by email as soon as it ships.

You might also like

More at Placid Deals